Krolken commented Jul 8, 2021

On Profile generic the capture_period is stored in second. But in ProfileGenericBufferParser the capture_period is in minutes.

ProfileGenericBufferParser should be changed to seconds so that the value from a meter can be used directly without transformation into minutes.