65 changes: 59 additions & 6 deletions 2019/19xxx/CVE-2019-19276.json
Original file line number Diff line number Diff line change
@@ -1,17 +1,70 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-19276",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels",
"version": {
"version_data": [
{
"version_value": "All versions < V16 Update 4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash.\nA manual restart of the device is required to resume operation of the service.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf"
}
]
}
Expand Down
2 changes: 1 addition & 1 deletion 2020/15xxx/CVE-2020-15798.json
Original file line number Diff line number Diff line change
Expand Up @@ -56,7 +56,7 @@
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)"
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)\n"
}
]
},
Expand Down
75 changes: 69 additions & 6 deletions 2020/25xxx/CVE-2020-25242.json
Original file line number Diff line number Diff line change
@@ -1,17 +1,80 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-25242",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions). Specially crafted packets sent to TCP port 102 could cause a Denial-of-Service condition\non the affected devices. \nA cold restart might be necessary in order to recover.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-676775.pdf"
}
]
}
Expand Down
4 changes: 2 additions & 2 deletions 2020/28xxx/CVE-2020-28392.json
Original file line number Diff line number Diff line change
Expand Up @@ -19,7 +19,7 @@
"version": {
"version_data": [
{
"version_value": "All versions"
"version_value": "All versions < V4.0.1"
}
]
}
Expand All @@ -46,7 +46,7 @@
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMARIS configuration (All versions). During installation to default target folder, incorrect permissions are configured for the application folder and subfolders which could allow an attacker to gain persistence or potentially escalate privileges should a user with elevated credentials log onto the machine."
"value": "A vulnerability has been identified in SIMARIS configuration (All versions < V4.0.1). During installation to default target folder, incorrect permissions are configured for the\napplication folder and subfolders which could allow an attacker to gain persistence or\npotentially escalate privileges should a user with elevated credentials log onto the machine.\n"
}
]
},
Expand Down
65 changes: 59 additions & 6 deletions 2020/28xxx/CVE-2020-28393.json
Original file line number Diff line number Diff line change
@@ -1,17 +1,70 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-28393",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SCALANCE XM-400 Family",
"version": {
"version_data": [
{
"version_value": "All versions < V6.4"
}
]
}
},
{
"product_name": "SCALANCE XR-500 Family",
"version": {
"version_data": [
{
"version_value": "All versions < V6.4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-682: Incorrect Calculation"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in SCALANCE XM-400 Family (All versions < V6.4), SCALANCE XR-500 Family (All versions < V6.4). The OSPF protocol implementation in affected devices incorrectly handles the number of LSA fields in combination with other modified fields.\n\nAn unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-116379.pdf"
}
]
}
Expand Down
85 changes: 79 additions & 6 deletions 2021/25xxx/CVE-2021-25660.json
Original file line number Diff line number Diff line change
@@ -1,17 +1,90 @@
{
"data_type": "CVE",
"data_format": "MITRE",
"data_version": "4.0",
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25660",
"ASSIGNER": "cve@mitre.org",
"STATE": "RESERVED"
"STATE": "PUBLIC"
},
"data_format": "MITRE",
"data_version": "4.0",
"data_type": "CVE",
"affects": {
"vendor": {
"vendor_data": [
{
"vendor_name": "Siemens",
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels 7\\\" & 15\\\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Panels 4\\\" - 22\\\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions < V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions < V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions < V16 Update 4"
}
]
}
}
]
}
}
]
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-788: Access of Memory Location After End of Buffer"
}
]
}
]
},
"description": {
"description_data": [
{
"lang": "eng",
"value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided."
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels 7\\\" & 15\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 4). SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition.\n"
}
]
},
"references": {
"reference_data": [
{
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
}
]
}
Expand Down
Loading