4 changes: 2 additions & 2 deletions ultimaker_absr_175.xml.fdm_material
Original file line number Diff line number Diff line change
Expand Up @@ -8,7 +8,7 @@
</name>
<GUID>88c8919c-6a09-471a-b7b6-e801263d862d</GUID>
<reference_material_id>abs-wss1</reference_material_id>
<version>8</version>
<version>9</version>
<color_code>#8cb219</color_code>
<description>Tough and durable. ABS is good for mechanical parts. It is impact resistant, dimensionally stable and handles temperatures up to 85ºC.</description>
<adhesion_info>No glue needed</adhesion_info>
Expand Down Expand Up @@ -55,7 +55,7 @@
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method XL" />
<setting key="build volume temperature">85</setting>
<setting key="heated bed temperature">95</setting>
<cura:setting key="material_bed_temperature_layer_0">100</cura:setting>
<cura:setting key="material_bed_temperature_layer_0">95</cura:setting>
<hotend id="1A">
<setting key="hardware compatible">no</setting>
</hotend>
Expand Down
6 changes: 3 additions & 3 deletions ultimaker_nylon12-cf_175.xml.fdm_material
Original file line number Diff line number Diff line change
Expand Up @@ -8,7 +8,7 @@
</name>
<GUID>3c6f2877-71cc-4760-84e6-4b89ab243e3b</GUID>
<reference_material_id>nylon12-cf</reference_material_id>
<version>6</version>
<version>7</version>
<color_code>#0e0e10</color_code>
<description>Nylon is strong, abrasion-resistant, durable and engineered for low moisture sensitivity.</description>
<adhesion_info>Use glue.</adhesion_info>
Expand All @@ -22,8 +22,6 @@
<settings>
<setting key="print temperature">270</setting>
<setting key="standby temperature">200</setting>
<setting key="heated bed temperature">95</setting>
<setting key="build volume temperature">85</setting>
<setting key="print cooling">0</setting>
<setting key="hardware compatible">yes</setting>
<cura:setting key="material_shrinkage_percentage">100.44</cura:setting>
Expand Down Expand Up @@ -77,6 +75,8 @@

<machine>
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method XL" />
<setting key="build volume temperature">85</setting>
<setting key="heated bed temperature">95</setting>
<hotend id="1A">
<setting key="hardware compatible">no</setting>
</hotend>
Expand Down
32 changes: 30 additions & 2 deletions ultimaker_pva_175.xml.fdm_material
Original file line number Diff line number Diff line change
Expand Up @@ -8,7 +8,7 @@
</name>
<GUID>add51ef2-86eb-4c39-afd5-5586564f0715</GUID>
<reference_material_id>pva</reference_material_id>
<version>4</version>
<version>5</version>
<color_code>#f5f2d1</color_code>
<description>Water soluble support material. PVA is a matching support material for PLA and Nylon 12 CF.</description>
<adhesion_info>Do not attempt to print PVA directly on your build surface, PVA needs a layer of model material below to ensure proper adhesion.</adhesion_info>
Expand All @@ -31,10 +31,38 @@
<machine>
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method" />
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method X" />
<setting key="print temperature">210</setting>
<setting key="standby temperature">160</setting>
<setting key="build volume temperature">60</setting>
<setting key="print cooling">0</setting>
<cura:setting key="prime_tower_enable">=extruder_nr==support_extruder_nr or extruder_nr==raft_base_extruder_nr or extruder_nr==raft_interface_extruder_nr or extruder_nr==raft_surface_extruder_nr</cura:setting>
<cura:setting key="support_conical_enabled">False</cura:setting>

<hotend id="1A">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="1XA">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="2A">
<setting key="hardware compatible">yes</setting>
</hotend>
<hotend id="2XA">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="1C">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="LABS">
<setting key="hardware compatible">no</setting>
</hotend>
</machine>
<machine>
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method XL" />
<setting key="print temperature">210</setting>
<setting key="standby temperature">160</setting>
<setting key="build volume temperature">40</setting>
<setting key="build volume temperature">60</setting>
<setting key="heated bed temperature">60</setting>
<setting key="print cooling">0</setting>
<cura:setting key="prime_tower_enable">=extruder_nr==support_extruder_nr or extruder_nr==raft_base_extruder_nr or extruder_nr==raft_interface_extruder_nr or extruder_nr==raft_surface_extruder_nr</cura:setting>
<cura:setting key="support_conical_enabled">False</cura:setting>
Expand Down
27 changes: 24 additions & 3 deletions ultimaker_sr30_175.xml.fdm_material
Original file line number Diff line number Diff line change
Expand Up @@ -8,7 +8,7 @@
</name>
<GUID>77873465-83a9-4283-bc44-4e542b8eb3eb</GUID>
<reference_material_id>sr30</reference_material_id>
<version>5</version>
<version>6</version>
<color_code>#f5f2d1</color_code>
<description>Dissolvable support material works seamlessly with ABS, ASA, and various other high-temp materials.</description>
<adhesion_info>Use the same temperatures and adhesion method as your build material(s).</adhesion_info>
Expand All @@ -24,8 +24,6 @@
<!-- print settings -->
<setting key="print temperature">255</setting>
<setting key="standby temperature">175</setting>
<setting key="build volume temperature">107</setting>
<setting key="heated bed temperature">60</setting>
<setting key="print cooling">0</setting>

<!-- Define as soluble support material -->
Expand All @@ -35,7 +33,30 @@

<machine>
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method X" />
<setting key="build volume temperature">107</setting>
<hotend id="1A">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="1XA">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="2A">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="2XA">
<setting key="hardware compatible">yes</setting>
</hotend>
<hotend id="1C">
<setting key="hardware compatible">no</setting>
</hotend>
<hotend id="LABS">
<setting key="hardware compatible">no</setting>
</hotend>
</machine>
<machine>
<machine_identifier manufacturer="Ultimaker B.V." product="UltiMaker Method XL" />
<setting key="build volume temperature">85</setting>
<setting key="heated bed temperature">95</setting>
<hotend id="1A">
<setting key="hardware compatible">no</setting>
</hotend>
Expand Down